Fan Beam Dexa Bone Densitometer With 64 Channels Fan Beam Dexa Bone Densitometer With 64 Channels Fan Beam Dexa Bone Densitometer With 64 Channels Fan Beam Dexa Bone Densitometer With 64 Channels Fan Beam Dexa Bone Densitometer With 64 Channels

Fan Beam Dexa Bone Densitometer With 64 Channels

3500000 INR/Unit

Product Details:

  • Power 220 Volt (v)
  • Product Type Fan Beam Dexa Bone Densitometer With 64 Channels
  • Suitable For Hospital
  • Supply Ability : 1 Unit Per Day
  • Click to view more
X

Price And Quantity

  • Any Order Unit
  • 3500000 INR/Unit

Product Specifications

  • Hospital
  • Fan Beam Dexa Bone Densitometer With 64 Channels
  • 220 Volt (v)

Trade Information

  • Cash Advance (CA)
  • 1 Unit Per Day
  • 7 Days
  • All India

Product Description

Because of its uses and market audit, we are producing and providing subjective Fan Beam Dexa Bone Densitometer With 64 Channels to our important customers that is made by utilizing best quality required materials with the assistance of most recent innovation. It utilizes a double energy x-beam source to survey bone mineral substance in the pivotal skeleton. The provided Bone Densitometer is a convenient box-like structure with a space for the foot or lower arm to be set for imaging.

Dexa Bone Densitometer (DEXA, DXA)

Bone densitometry, also called dual-energy x-ray absorptiometry, DEXA or DXA, uses a very small dose of ionizing radiation to produce pictures of the inside of the body (usually the lower (or lumbar) spine and hips) to measure bone loss. It is commonly used to diagnose osteoporosis, to assess an individual's risk for developing osteoporotic fractures. DXA is simple, quick and noninvasive. It's also the most commonly used and the most standard method for diagnosing osteoporosis.

Why our Dexa?

1. Very Low radiation to patient & operator

2. Very little scatter radiation to technologist

Fan Beam Dexa Bone Densitometer with 64 Channels 

X-ray bone densitometer is a medical device that can measure bone mineral density and check osteoporosis. We use dual energy X-ray absorptiometry (DXA) using low-energy X-ray and high-energy X-ray attenuation. The X-rays emitted from the X-ray generator pass through the tissues adjacent to the patient's bones and then detected by the FAN Beam method at the detector. The detected X-rays are analyzed with two energies (high energy and low energy).

The BMD values measured in this way are faster and more accurate.

You can check osteoporosis by comparing and analyzing result data with reference data.

 

  • Scan type: FAN beam
  • Measuring time: spine (about 30 sec), Femur (about 30 sec), Forearm (about 30 sec), Lateral Spine (about 30 sec), LVA (about 60 sec), Half Body (about 180 sec)
  • Standard scan site: AP Spine, L/R Femur 
  • Optional function: L/R Forearm, Lateral spine, LVA, Half body composition
  • Precision: < 1% CV (1.0g/cm²)
  • Accuracy: ± 1% 
  • Auto ROI : Automatic ROI (region of interest) classification after measuring
  • Radiation dose: Less than 10mRem per 1 time
  • System interlock: Supports DICOM and Maria DB compatibility between different systems.
  • Multiple output feature: Results, patient information, BMD, trend output
  • Trend comparison : Trend data comparison of each region
  • History: you can see the record of the patient in the past.

 

 Technical Specifications

 

Category

Description

Note

 

Main body

Manufacturer

MEDIKORS INC.

 

Model name

InAlyzer-Air

 

Grade and type

Classb, B type device

 

Product size

1850(W)x800(D)x1162(H)

 

Weight

138Kg

 

Input voltage and frequency

110V 50/60Hz, 220V-230V 50/60Hz,

 

Power consumption

800VA

 

Expiration date

10 years

 

Operation Mode

Non-Continuous

 

Classification of Electric shock and Applied part

Class1 Type B

 

Scan area

490mm x 900mm

 

 

X-ray generator (MEDI-024)

Manufacturer

MEDIKORS INC.

 

S/N

1611802

 

Model name

MEDI-024

 

MAX output power

300W

 

Input Power

AC200-240

 

tube voltage

40~100kV (±10%)

 

tube current

0.15~3(±20%)

 

Max. power consumption

300 watts

 

Capacity

500W

 

Input voltage and frequency

110V 50/60Hz, 220V-230V 50/60Hz

 

Aluminum equivation

2.0mmAL (X-ray tube)

 

Max exposure time

3min

 

 

X-ray tube (DF-151SBR)

Manufacturer

Toshiba

 

S/N

02199

 

Model Name

DF-151SBR

 

AC Input

90~264Vac, 50Hz~60Hz

 

tube voltage

40-110kV

 

tube current

L: 60mA S:15mA

 

Input voltage and frequency

110VAC/220VAC ±10%

 

Lowest Current Time product

1mAs (0.2mA, 5seconds)

 

Inherent Filtration

At least 0.8 mm Al equivalent at 50KV

 

Total Filtration

2.8 Al

 

Focal Point Size

0.5

 

Heat capacity

34KJ

 

Target Angel

16 degrees

 

 

SMPS

AC Input

90~264 VAC, 47~63 Hz

 

Output

24 V, 6.5 A

 

 

Detector

Model name

InAlyzer AIR Detector

 

Photographing device

PhotoDiode

 

Photographing area

64 Channels array (Low, High Total 128channels)

 

 

Daily Check Phantom

Manufacturer

MEDIKORS INC.

 

Model name

Daily Phantom

 

Size

195(W) x 145(D) x 50(H)

 

 

Performances

Image size (spine)

150mm X 200mm

 

Image size (Femur)

150mm X 200mm

 

Precision

< 1% CV

 

Accuracy

± 1% error range

 

Patient weight

135kg under

 

X-ray radiation time

Within an average of 30 seconds per site (The LVA site is about 90 seconds and the Half body is about 180 seconds)

 

Radiation exposure

below 1000uSv/h at 1m

247.152uSv/h

 

Use environment

Operating temperature

10-40

 

Optimal humidity

20-50%

 

Optimal pressure

700 - 1060 Hpa

 

Storing temperature

-40 to +70

 

Storing humidity

10% - 40%

 

Storing pressure

700 - 1060 Hpa

 

 

 Specification

Type

Full Body Dexa

Footprint

Flatbed

Design Type

Fan Beam 64 Channel

Result Time

26-31 sec

Measuring Parameter

BMD

Measurement Type

X-Ray

 

Item

Item details

Value

Performance

Precision

 

No of channels

 

Image Resolution

 

Scan Area

 

Scan time

Ap spine

30 sec

L-spine (option)

60 sec

Right left femur

30 sec

LVA (option)

90 sec

Right left forearm

30 sec

Half body (option)

180 sec

Measurement parameter

BMD. BMC Fat% Lean

 


AARNA SYSTEMS AND WELLNESS PVT. LTD.

* Tips on getting accurate quotes. Please include product name, order quantity, usage, special requests if any in your inquiry.



Back to top